ComputerBath® Power Cleaner MSDS
|
Page # :1 Product: # 00016 ComputerBath® Effective: 03/2007 Emergency Phone # (949-939-9904) *** MATERIAL SAFETY DATA SHEET *** *** SECTION I - PRODUCT IDENTIFICATION *** ******* MANUFACTURER ******* ComputerBath® POWER CLEANER A DIV. OF ORLOFF CORPORATION 25108 Marguerite PWKY B218 Mission Viejo, CA 92692 949-939-9904 Contact Dennis Orloff HAZARD RATING HMIS NFPA Health : 2 Moderate Flammability : 0 Insignificant Reactivity : 0 Insignificant *** SECTION II - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION *** CAS # INGREDIENTS WEIGHT %2.00 141-43-5 {PA,MA,NJ} Ethanolamine EXPOSURE LIMIT : 3 ppm ACGIH TWA : 7.5 mg/m3 ACGIH TWA : 6 ppm ACGIH STEL : 15 mg/m3 ACGIH STEL : 3 ppm OSHA PEL : 6 mg/m3 OSHA PEL See Regulatory Information (Section XII) for explanation of bracketed information. *** SECTION III - PHYSICAL DATA *** APPEARANCE/ODOR...................: Green/Mint odor SPECIFIC GRAVITY..................: 1.006 VAPOR PRESSURE - (mm Hg)..........:Not Tested PERCENT VOLATILE BY VOLUME (%).... SOLUBILITY IN WATER...............: 100% VAPOR DENSITY (Air=1)............. Not Tested FREEZING POINT (*F)............... BOILING POINT (*F)................: 210 F pH................................: 12-13.5 EVAPORATION RATE (Butyl Acetate=1): Not Tested VOC (as packaged, minus H2O(Water): THEORETICAL VOC (lb/gal)..........: *** SECTION IV - FIRE AND EXPLOSION INFORMATION *** FLASH POINT (*F) (Method Used): None FLAMMABLE LIMITS: Not Tested EXTINGUISHING MEDIA: None SPECIAL FIRE FIGHTING PROCEDURES: None |
|
Page # :2 Product: 00016 ComputerBath® Effective:03/2007 Emergency Phone # (949-939-9904) *** MATERIAL SAFETY DATA SHEET *** *** SECTION IV - FIRE AND EXPLOSION INFORMATION *** UNUSUAL FIRE AND EXPLOSION HAZARDS: None *** SECTION V - HEALTH HAZARD DATA *** PRIMARY ROUTE OF ENTRY: Inhalation: Possible; Skin: Possible; Ingestion: Possible SIGNS AND SYMPTOMS: Eyes: Burning irritation Skin: Irritation Ingestion: Toxic Inhalation: Slight irritation FIRST AID PROCEDURES: Eyes: Flush well with water for 15 minutes. If irritation persists, call physician. Skin: Wash with soap and water. If irritation persists, call physician. Ingestion: Give large amounts of water to dilute. Call physician. Inhalation: Move person to fresh air. If unconscious, contact physician. MEDICAL CONDITIONS GENERALLY RECOGNIZED AS BEING AGGRAVATED BY EXPOSURE: Same as signs and symptoms of over exposure. *** SECTION VI - REACTIVITY DATA *** STABILITY: Stable STABILITY - CONDITIONS TO AVOID: None INCOMPATIBILITY: Acidic materials HAZARDOUS DECOMPOSITION PRODUCTS: None HAZARDOUS POLYMERIZATION: Will not occur HAZARDOUS POLYMERIZATION - CONDITIONS TO AVOID: None *** SECTION VII - SPILL OR LEAK PROCEDURES *** STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Soak up with inert, absorbent material. Scoop up and place in a proper waste disposal container. WASTE DISPOSAL INFORMATION: Dispose of in accordance with state and local regulations. *** SECTION VIII - SPECIAL PROTECTION INFORMATION *** RESPIRATORY PROTECTION: Open all doors and windows. Exposures above the TLV or PEL require a NIOSH approved respirator equipped for the exposure of suitable respiratory protection per 29 CFR 1910.134. VENTILATION: |
|
Page # : 3 Product: 00016 ComputerBath ® Effective: 03/2007 Emergency Phone # 949-939-9904 *** MATERIAL SAFETY DATA SHEET *** *** SECTION VIII - SPECIAL PROTECTION INFORMATION *** Local exhaust - if available Mechanical - if available PROTECTIVE GLOVES: Rubber/Plastic EYE PROTECTION: Glasses/Goggles OTHER PROTECTIVE MEASURES: None *** SECTION IX - SPECIAL PRECAUTIONS *** PRECAUTIONARY LABELING: Keep out of reach of children. Follow directions on the container for proper use of the product. OTHER HANDLING AND STORAGE CONDITIONS: Store in a cool, dry place out of direct sunlight. Do not freeze or heat above 110 F. *** SECTION X - ADDITIONAL INFORMATION *** ADDITIONAL INFORMATION: Basic Directions ……… Water activated formula used for common cleaning. Use full strength for electronics cleaning. Never clean equipment when its running. Never start equipment when unit is damp. Work Hygienic Practices: Use common sense and care around chemicals. Never mix chemicals. Consult your supervisor for other practices. All practices depend on your specific business. Directions for use are normally found on label which will dictate engineering and control measures. Non Carcinogenic. *** SECTION XI - TRANSPORTATION INFORMATION *** DOT CLASS: DOT #: None SHIPPING NAME: DOT NOTES: N/A *** SECTION XII - REGULATORY INFORMATION *** These ingredients are subject to the reporting requirements under the Massachusetts Hazardous Substance List. These ingredients are subject to the reporting requirements under the New Jersey Right to Know Hazardous Substance List. These ingredients are subject to the reporting requirements under the Pennsylvania Hazardous Substance List. The disclosures and information set forth on this sheet were provided by manufacturers and distributors who provide products for Orloff Corporation. Orloff Corporation does not warrant the accuracy, *** SECTION XII - REGULATORY INFORMATION *** completeness or legality of such disclosures or information, or that Orloff Corporation has correctly and completely reproduced and copied the same. ComputerBath Ć is a registered trademark of
Orloff Corporation. Reproduction is not authorized to use unless written
permission is given. |
ComputerBath®
25108
Marguerite PWKY B218, B218, Mission Viejo, CA 92692
Phone:
949-939-9904
Fax: 949-859-2458
©2000
ComputerBath. ComputerBath® is a registered trademark of the Orloff
Corporation.